CTSNet
Browse
- No file added yet -

Respecting The Mitral With Home-Made Loops

Download (281.27 MB)
media
posted on 2021-05-13, 20:58 authored by Abdelrahman Abdelbar, Grzegorz Laskawski, Joseph Zacharias

In this video, we have used a home-made chord loops for mitral valve repair. We believe that this system is flexible for the mitral surgeons as the number of loops can be controlled. Usually, we use the Chordex system made by On-X, but due the shortage of supplies we faced due the pandemic, we started to make this system intraoperatively.

We usually use size 16mm chords for posterior mitral leaflet and 20-24mm chords for anterior mitral leaflet. So far, we have used this system in a large number of patients with good results.

References
1. 1. RANGANATHAN N, LAM J, WIGLE E, SILVER M. Morphology of the Human Mitral Valve. Circulation. 1970;41(3):459-467.

2.2. Suri R. Chordae Replacement Versus Resection for Repair of Isolated Posterior Mitral Leaflet Prolapse: À Ègalité. Yearbook of Cardiology. 2010;2010:240-242.