posted on 2020-07-29, 21:41 authored by Sameh Said, Gustavo Orellana, Ranjit John

This is the case of a 65-year-old woman who presented with exertional dyspnea, fatigue, and a long history of chronic hemolytic anemia. She had a complex cardiac surgical history with four previous sternotomies to address mitral valve (MV) pathology. The patient had three previous MV replacements with mechanical prostheses (St. Jude twice and Starr Edwards once). She also had previous repair of periprosthetic mitral regurgitation and tricuspid DeVega annuloplasty. Due to recurrent periprosthetic mitral regurgitation, transcatheter device closure was attempted but was unsuccessful. Other significant medical history included: rheumatic fever at age 16, chronic atrial fibrillation, hypertension, pectus excavatum, and chronic hepatitis C.

Preoperative studies included routine chest X-ray, CT scan, echocardiography, and hemodynamic cardiac catheterization. Major findings were cardiomegaly, with severely dilated left atrium, severe mitral annular calcifications (MAC), aortic arch calcifications with close proximity of both innominate vein and ascending aorta to the back of the sternum, severe periprosthetic mitral regurgitation, combined aortic valve (AV) regurgitation and stenosis, and recurrent severe tricuspid valve (TV) regurgitation. On hemodynamic catheterization, there were markedly elevated right-sided pressure with elevated pulmonary vascular resistance, which responded favorably to oxygen and sodium nitroprusside.

The procedure was performed through a fifth time sternotomy, with right axillary artery cannulation. Using a combined extended Manouguian posterior aortic root enlargement and Guiraudon extended vertical transseptal approaches, the authors were able to have adequate exposure to explant the previously placed Starr-Edwards prothesis, decalcify the posterior mitral annulus, enlarge both aortic and mitral valves annuli, and place adequate size mechanical aortic and mitral prostheses (25 mm and 29 mm St. Jude mechanical prostheses). A concomitant tricuspid valve replacement was also performed using a leaflet-sparing approach and a 29 mm St. Jude Epic Bioprosthesis was placed.

The postoperative course was uneventful. Delayed sternal closure was performed 48 hours later. She was discharged home two weeks later and did not require pacemaker placement. Follow-up echocardiography demonstrated well-functioning prostheses with single digit gradient across all prostheses. She continued to do well at her last follow-up.

References

  1. David TE, Kuo J, Armstrong S. Aortic and mitral valve replacement with reconstruction of the intervalvular fibrous body. J Thorac Cardiovasc Surg. 1997;114:762–772.
  2. Pettersson GB, Hussain ST, Ramankutty RM, Lytle BW, Blackstone EH. Reconstruction of fibrous skeleton: technique, pitfalls and results. Multimed Man Cardiothorac Surg. 2014;2014:mmu004.
  3. Said SM. Mitral valve bypass: Another extra-anatomic solution for another tiger territory? J Thorac Cardiovasc Surg. 2019 Apr;157(4):e147-e148.
  4. Manouguian S, Seybold-Epting W. Patch enlargement of the aortic valve ring by extending the aortic incision into the anterior mitral leaflet. New operative technique. J Thorac Cardiovasc Surg. 1979 Sep;78(3):402-412.
  5. Manouguian S, Kirchhoff PG. Patch enlargement of the aortic and the mitral valve rings with aortic-mitral double valve replacement. Ann Thorac Surg. 1980;30:396-399.