COVID-19: Safe Thoracic Surgery
Providing lung cancer surgery during the COVID-19 crisis
presents many challenges. Cancer services must minimize exposure to health care
workers and manage the higher risks associated with surgery during the pandemic,
while also contending with reduced elective operating and intensive care
capacity (1).
COVID-19 has proved to be highly infectious and has infected more people in a
shorter time period than other coronavirus outbreaks (SARS-CoV and MERS-CoV) (2).
The lungs are the primary organ affected by COVID-19, and transmission is
caused by respiratory droplets, airborne transmission, and direct contact, making
lung cancer surgery high risk for healthcare worker infection (2).
Guidelines from the British Thoracic Society advise consideration of
stereotactic ablative radiotherapy (SABR) in patients with tumors under 2 cm
and prioritizing surgical management for patients with higher stage cancers
which are likely to become unresectable if treatment is delayed (3). The advice
from NHS England is clear and states that essential and urgent cancer
treatments must continue (4).
As well as the surgical risk of infection to health care workers, there is also
the risk of aerosolization of the virus from a chest drain with an air leak.
Anecdotal reports from other thoracic units suggest that this is a problem,
with reports of entire wards being infected after a postoperative patient was
found to have COVID-19. The authors are unaware of any specific guidance on
chest drain management during the COVID-19 pandemic. Under normal working
conditions, NICE recommends the use of Thopaz drains following lung resection.
However, after contacting the manufacturer, these drains do not have a viral
filter (5). Extrapolating advice from NHS England on ventilator circuits which
should be protected by a high efficiency filter such as a heat and moisture
exchange (HME) filters, the authors have developed a method of providing chest
drainage with a viral filter (6). The authors have previously described the
idea of the attachment of viral filters to Rocket bottles (7). In this article,
the authors aim to improve it further and update on some of the pitfalls with
this new set-up.
The set-up is simple and uses equipment that is easily available (Rocket bottle
with tubing and a Therm 3 HME filter or alternatively a high efficiency heat
filter (Figure 1)). In addition to the suction port, the Rocket bottle has additional
safety holes that provide a mechanism for air to escape should the suction
become blocked (Figure 1D). If the Rocket bottle is to be used with a viral
filter, then these must be covered to prevent the virus being aerosolized
through this lower resistance mechanism. This can be done easily with stickers
which are provided with the bottle. However, covering these holes puts the
patient at risk of developing a tension pneumothorax should the viral filter
block or if attached incorrectly.
Checking the viral filter must be part of standard nursing
checks for all patients with chest drains. The air leak is monitored and any
sudden changes in air leak mandate a medical review. The authors have tested
the resistance to flow of the HME filter on a ventilator up to a flow rate of
30 L/min, and even at this flow rate resistance is trivial. This has correlated
with their clinical experience that the presence of a filter does not impede
the air flow out of the chest in patients with air leaks as demonstrated by the
chest radiograph showing no pneumothorax. Filters are changed daily as per
manufacturer recommendation or sooner if there is any gross contamination. This
is done wearing full personal protective equipment (PPE). Additionally, PPE is
worn for changing Rocket bottles and for chest drain removal. The same filter
system can also be applied to a Portex bag (Figure 1E), which aims to
facilitate mobilization on the ward.
In addition to this chest drain management, the authors developed a number of
ways of minimizing the risk of COVID- 19 transmission. Patients are admitted on
the morning of surgery and immediately taken for a low dose computerized
tomography (CT) scan of the chest as per guidelines from the Royal College of
Surgeons (8). Chinese studies have shown that chest CT has sensitivity as high
as 97% for COVID-19 detection (9). Even in asymptomatic patients with COVID-
19, CT abnormalities were found in 95% of cases (10). The authors aim to start
taking viral swabs two days prior to surgery in addition to the CT scan in
keeping with Royal College of Surgeons recommendations (11). Providing the CT
scan is negative for COVID-19 changes, then the operation is performed with all
theatre staff wearing full PPE. Every effort is made to minimize air leaks,
intra-operatively lung tissue is stapled and air leaks assessed at the end of
the case with underwater testing and repaired where possible. The chest drain
is connected at the end of the procedure and the air leak is assessed, the
viral filter is placed, and the safety holes are covered.
This multifaceted strategy allows the authors to continue to provide thoracic
surgery during the COVID-19 crisis and minimize risks to patients and staff.
Future work would be to ascertain the viral load in chest drains of COVID-19
patients who require chest drainage. This method serves as an interim method of
lowering the risk of viral exposure to the other patients and staff in
hospitals.
Reference(s)
1. Li YK, Peng S, Li LQ, Wang Q, Ping W, Zhang N, et al. Clinical and transmission characteristics of Covid-19 - A retrospective study of 25 cases from a single thoracic surgery department. Curr Med Sci. 2020 Mar 30.
2. Meo SA, Alhowikan AM, Al-Khlaiwi T, Meo IM, Halepoto DM, Iqbal M, et al. Novel coronavirus 2019-nCoV: prevalence, biological and clinical characteristics comparison with SARS-CoV and MERS-CoV. Eur Rev Med Pharmacol Sci. 2020 Feb;24(4):2012-2019.
3. Matthew Evison, Seamus Grundy, Simon Bailey, Richard Booton, Rajesh Shah, Neil Bayman, et al. Lung cancer and mesothelioma service guidance during the COVID‐19 pandemic. NHS England Clinical Expert Group on Lung Cancer.
5.
Thopaz+ portable digital system for managing
chest drains
Medical technologies guidance [MTG37] Published date: 21 March 2018