10.25373/ctsnet.6810035.v1 Stefan Welter Stefan Welter Endotracheal Repair of an Iatrogenic Tracheal Laceration CTSNet 2018 Thoracic Trachea Surgery 2018-07-18 16:55:34 Media https://ctsnet.figshare.com/articles/media/Endotracheal_Repair_of_an_Iatrogenic_Tracheal_Laceration/6810035 <div>The author presents an endotracheal repair, performed for a 72-year-old woman who was mechanically ventilated for a heart failure due to lung edema and hypoxia. She developed severe mediastinal and subcutaneous emphysema due to a 4.5 cm iatrogenic tracheal laceration. A completely endotracheal repair with a running suture was performed using the optical needle holder from Karl Storz Company (Tuttlingen, Germany). The patient needed prolonged ventilation for the underlying disease but could be weaned from ventilation on postoperative day 13. No complications arose.</div><div><p><strong>Suggested Reading</strong></p><ol><li>Welter S, Krbek T, Halder R, Stamatis G. A new technique for complete intraluminal repair of iatrogenic posterior tracheal lacerations. <em><a href="https://doi.org/10.1510/icvts.2010.248641">Interact Cardiovasc Thorac Surg. 2011;12(1):6-9</a></em>.</li><li>Welter S. Repair of tracheobronchial injuries. <em><a href="https://doi.org/10.1016/j.thorsurg.2013.10.006">Thorac Surg Clin. 2014;24(1):41-50</a></em>.</li></ol></div><div><br></div>